You are here:
SURVIVOR CL4040

GENERAL INFORMATION

Mounting ModuleZ track system (standard)
Busbar bracket system (optional)
Angle bracket system (optional)
Earthquake hanger system (optional)
Operating Temperature -20 °C / +40°C (standard)
-20 °C / +80°C (optional,HOT PLUS)
-40 °C / +65°C (optional,COLD PLUS)
Storage Temperature-40°C / +80°C
Glass Mounting
Options
Tool-free clips system
LED ModulesRemovable / Replaceable optical unit
Lens Options30° (High-Bay), 60° (Mid-Bay),
90° (Low-Bay)(Standart),
120° (Extra Low-Bay), 39°x90° (Corridor),
Project-specific lens selection (optional)
Main Reference
Company Standards
EN 60598-1, EN 60598-2-1, EN 62471,
EN 60068-2-11, EN60068-2-52, ISO9227,
ASTMB117, ASTMD3359-78, ISO 4628-2,
ISO 4628-4, EN 60529, EN 62262,
ANSIC136.10-2017, ANSI C136.2-2018, EN 62031,
IEC 62384, ASTM D3359, EN ISO 2409,
IES LM 80-15, IES LM 82-12, IES LM 84,14,
IES LM 85-14, IES TM 21-11, ISO9001, ISO14001,
ISO18001, ISO5001, TS EN/ISO 17025

ELECTRICAL INFORMATION

Electrical ClassClass I, Class II (optional)
Nominal Voltage220-240V 50/60 Hz EU
110-277V 50/60 Hz (optional) NORTH AMERICA
Led Current250mA, 350mA, 400 mA, 450mA, 500mA,
600mA, 700mA, 900mA, 1050mA, 1200mA
Power Factor≥0.9 (at full load)
DriverConstant current, Thermal protected,
Voltage regulated, Harmonic filter protection
Surge protection
options (kV)
6 kV (optional)
10 kV (optional) with LED signal and thermo
fuse to disconnect load at the end of life
20 kV (optional) with LED signal and thermo
fuse to disconnect load at the end of life
Control systemon-off (standard), Bluetooth, DALI, 1-10V DIM,
Stand alone automation
SocketNEMA 4-pin (ZHAGA book 18) (optional)
NEMA 5-pin (ANSI C136.41)(optional)
NEMA 7-pin (ANSI C136.41)(optional)
SensorPIR (optional), Photocell (optional),
Daylight (optional)
Mains connectionFor cable max section 2,5 mm2
Outgoing cable H05RN-F 2/3/5 x 1,5 mm2
Length on request.(optional)
Electromagnetic
compatibility
(EMC)
IEC 61000, EN 55015, IEC 61000-3-2, IEC 61000-4-5,
IEC 61547, IEC 61000-3-3, IEC 61000-4-2, IEC
61000-2-2, IEC 61000-4-11, IEC 61643-11

HOUSING AND MATERIALS

HousingCorrosion resistant aluminum extrusion
OpticPMMA or PC
Gasket Silicon or polyurethane without junction points
RefractorTempered glass min. 4mm high transparecy
UV resistant (optional)
Standard ColourRAL830
Anti-microbial (optional)
Project-specific colour selection
Tightness LevelIP66
Impact Housing ResistanceIK10 (20 J)
Impact Glass ResistanceIK09 (standart) (10 J), IK10 (opsiyonel) (20 J)
Vibration TestIEC 68-2-6 (0.5G), ANSI C136.31 (3G-5G)
CapGlass-fibre UV stabilized, auto extinguishing
recyclable polymer (RAL7035)
Connector5 pin terminal connector

OPTICAL INFORMATION

Led colour
temperature
2700K (warm white), 3000K (warm white),
4000K (neutral white) (standard),
5000K (cool white), 5700K (cool white),
6500K (cool white)
Colour rendering
ındex (CRI)
CRI ≥80
CRI ≥90 (optional)
Upward light
output ratio
0%
Photobiological
safety class
IEC 62471, EN 62778 EXEMPT GROUP
Testing standardLM 79-19 , EN 13032-1, EN 13032-2, (all
measurements in ISO17025 accredited laboratory)
Lifetime of the LED's Tq= 25°C, >102.000h - L70
Tq= 55°C, >102.000h - L70

Main Application

Survivor-icon-2