You are here:
Ice Reflect CL311

GENERAL INFORMATION

Operating Temperature-20 °C / +50°C
Storage Temperature-40°C / +80°C
Ceiling OptionsT2. recessed ceiling installation tools
Main Reference
Company Standards
EN 60598-1, EN 60598-2-2, EN 62471,
EN 60068-2-11, EN60068-2-52, ISO9227,
ASTMB117, ASTMD3359-78, ISO 4628-2,
ISO 4628-4, EN 60529, EN 62262,
ANSIC136.10-2017, ANSI C136.2-2018,
EN 62031, IEC 62384, ASTM D3359,
EN ISO 2409, IES LM 80-15, IES LM 82-12,
IES LM 84,14, IES LM 85-14, IES TM 21-11,
ISO9001, ISO14001, ISO18001, ISO5001,
TURKAK, ISO45001, ISO39001, EAC

ELECTRICAL INFORMATION

Electrical ClassClass I, Class II (optional)
Nominal Voltage220-240V 50/60 Hz EU
110-277V 50/60 Hz ( optional) NORTH AMERICA
LED Lamp Power5W, 9W, 12W, 18W, 30W
Power Factor≥0.9 (at full load)
DriverConstant current
Thermal protected
Voltage regulated
Harmonic filter protection
Surge protection
options (kV)
1 Kv (standard)
Emergency Kit
(optional)
1 hour battery
3 hours batteries
Control systemOn-off (standard)
Bluetooth
DALI
1-10V DIM
Stand alone automation
Mains
connection
For cable max section 2,5 mm2
Outgoing cable H05RN-F 2/3/5 x 1,5 mm2 .
Length on request.(optional)
Electromagnetic
compatibility
(EMC)
IEC 61000, EN 55015, IEC 61000-3-2,
IEC 61000-4-5, IEC 61547, IEC 61000-3-3,
IEC 61000-4-2, IEC 61000-2-2,
IEC 61000-4-11, IEC 61643-11

HOUSING AND MATERIALS

HousingNon corressive high pressure die-cast aluminium
RefractorPMMA
Tightness LevelIP40

OPTICAL INFORMATION

Led colour
temperature
3000K (warm white)
6000K (cool white)
Colour rendering
ındex (CRI)
CRI ≥80
Upward Light
Output Ratio
(ULOR)
0%
Testing standardLM 79-19 , EN 13032-1 (all measurements in
ISO17025 accredited laboratory)
Lifetime of the
LED's
Tq= 25 ° , 700 Ma ≥ 50.000h -L70
Tq= 55 ° , 700 Ma ≥ 50.000h -L70

Main Application

IceReflectCL311-icon2