You are here:
SHARP C185

GENERAL INFORMATION

Mounting ModulePost top or side entry from 25-50Ø
Post top or side entry from 42- 60Ø
Spigot entry 100mm
Wall console (optional)
Standard Tilt AnglesPost top/side entry 0°
Operating Temperature-30 °C / +70°C
Storage Temperature-40°C / +80°C
Electrical KitRemovable kit
Tool free removable kit (optional)
Light OutputHSE/ HST
HIT-CE
Main Reference
Company Standards
EN 60598-1, EN 60598-2-3,EN 61347-2-9,
EN 60923, EN 61048,EN 61049,EN 60926,
EN 60068-2-11, EN60068-2-52, ISO9227,
ASTMB117, ASTMD3359-78, ISO 4628-2,
ISO 4628-4, EN 60529, EN 62262,
ANSIC136.10-2017, ANSI C136.2-2018, ASTM D3359,
EN ISO 2409, ISO9001, ISO14001, ISO18001,
ISO50001, TURKAK,ISO45001, ISO39001, EAC

ELECTRICAL INFORMATION

Electrical ClassClass I, Class II (optional)
Nominal Voltage220-240V 50/60 Hz ECG EU
220-240V 50 Hz CCG EU
220-240V 60 Hz CCG EU (Optional)
GearConventional
Bi-Level Conventional
Electronic
Lamp Power50W HSE/HST, 70W HSE/HST, 100W HSE/HST
150W HSE/HST, 35W HIT-CE, 70W HIT-CE
150W HIT-CE
Power Factor≥0.95
IgnitorCut-out type 5 min.(optional)
Cut-out type 10 min.(optional)
Cut-out type 20 min.(optional)
CapacitorDecharging resistor (optional)
Control
Options
On-off (standard)
Line swich bi-level control (optional)
Auto bi-level control (optional)
Mains
Connection
For cable max section 2,5 mm2
Outgoing cable H05RN-F 2/3/5 x 1,5 mm2
(optional)
Length on request.(optional)
Electromagnetic
Compatibility
(EMC) For
Electronic Ballast
IEC 61000, EN 55015, IEC 61000-3-2, IEC
61000-4-5, IEC 61547, IEC 61000-3-3, IEC
61000-4-2, IEC 61000-2-2, IEC 61000-4-11,
IEC 61643-11

HOUSING AND MATERIALS

HousingNon corressive high pressure die-cast aluminium
Pole Mounting
Module
Non-corresive die-cast aluminium
Gasket Silicon or polyurethane without junction points
Housing FinishUNI EN1706 powder painted
ReflectorOne-piece pressed anodised and
polished high grade aluminium
RefractorTempered glass min. 4mm high transparecy
UV resistant (optional)
Cable GlandIP66 ,Plastic PG13,5, IP67 (optional)
Standard ColourRAL9007
Tightness LevelIP66
Impact Housing
Resistance
IK09 (10 J)
Impact Glass
Resistance
IK08 (5 J), IK09 (optional) (10 J),
IK10 (optional) (20 J)
Vibration TestCompliant with modified IEC 68-2-6 (0.5G),
ANSI C136.31 (3G-5G)

OPTICAL INFORMATION

SocketE27, E40, G12
Socket Position3 different light beam position
Upward Light
Output Ratio
(ULOR)
0%
Testing StandardEN 13032-1 / EN 13032-2
ReflectorCR1100
CR2100 (Aluminium Injection)(Optional)

Main Application

SharpC185-icon2