GENERAL INFORMATION
Operating Temperature | -40 °C / +55°C |
Storage Temperature | -40°C / +80°C |
Light Output | HST / HIT |
Main Reference Company Standards | EN 60598-1, EN 60598-2-3,EN 61347-2-9, EN 60923, EN 61048,EN 61049,EN 60926, EN 60068-2-11, EN60068-2-52, ISO9227, ASTMB117, EN 60529, EN 62262, ANSIC136.10-2017, ANSI C136.2-2018, ISO9001, ISO14001, ISO18001, ISO50001, TURKAK, ISO45001, ISO39001, EAC |
ELECTRICAL INFORMATION
Electrical Class | Class I, Class II (optional) |
Nominal Voltage | 220-240V 50 Hz CCG EU 220-240V 60 Hz CCG EU (Optional) |
Gear | Conventional |
Lamp Power | 70W HST/HIT 100W HST/HIT 150W HST/HIT 250W HST/HIT 400W HST/HIT |
Power Factor | ≥0.95 |
Ignitor | Cut-out type 5 min.(optional) Cut-out type 10 min.(optional) Cut-out type 20 min.(optional) |
Capacitor | Decharging resistor (optional) |
Control Options | On-off (standard) |
Mains Connection | For cable max section 2,5 mm2 Outgoing cable H05RN-F 2/3/5 x 1,5 mm2 (optional) Length on request.(optional) |
HOUSING AND MATERIALS
Housing | Stainless steel AISI316 |
Gasket | Two step applied silicone foam gasket |
Refractor | Tempered glass min. 6mm high transparecy UV resistant (optional) |
Cable Gland | IP66 , Brass PG32 IP67 (optional) IP68 (optional) |
Tightness Level | IP66, IP67 (optional), IP68 (optional) |
Impact Housing Resistance | IK10 (20 J) |
Impact Glass Resistance | IK08 (5 J) IK09 (optional) (10 J) IK10 (optional) (20 J) |
Vibration Test | Compliant with modified IEC 68-2-6 (0.5G), ANSI C136.31 (3G-5G) |
OPTICAL INFORMATION
Socket | E40, E27 |
Upward Light Output Ratio (ULOR) | 0% |
Testing Standard | EN 13032-1 / EN 13032-2 |
Reflector | Symmetrical reflector Asymmetrical reflector |
Main Application